A change in #763 to address review comments caused problems. Originally,
instrumentedResponseWriter implemented the CloseNotifier interface, and
would panic if it was wrapping something that did not implement that
interface. This was split into a separate instrumentedResponseWriterCN
type that implements CloseNotifier, so there's a fallback if
instrumentedResponseWriter ever needs to wrap something that does not
implement this interface.
instrumentedResponseWriter's Value method would end up upcasting either
type back to instrumentedResponseWriter, which does not implement the
interface. In effect, instrumentedResponseWriterCN was never visible to
the handler.
This fixes the problem by implementing a wrapper Value method for
instrumentedResponseWriterCN.
Signed-off-by: Aaron Lehmann <aaron.lehmann@docker.com>
Instead, provide a variant of instrumentedResponseWriter that does not
implement CloseNotifier, and use that when necessary. In
copyFullPayload, log instead of panicing when we encounter something
that doesn't implement CloseNotifier.
This is more complicated than I'd like, but it's necessary because
instrumentedResponseWriter must not embed CloseNotifier unless there's
really a CloseNotifier to embed.
Signed-off-by: Aaron Lehmann <aaron.lehmann@docker.com>
The response code isn't actually sent to the client, because the
connection has already closed by this point. But it causes the status
code to appear as 499 in the logs instead of 0.
Signed-off-by: Aaron Lehmann <aaron.lehmann@docker.com>
This changeset provides a common http handler for serving errcodes. This should
unify http responses across webservices in the face of errors.
Several type assertions have been added, as well, to ensure the error interface
is implemented.
Signed-off-by: Stephen J Day <stephen.day@docker.com>
The goal is to free up the distribution/registry package to include common
registry types. This moves the webapp definitions out of the way to allow for
this change in the future.
Signed-off-by: Stephen J Day <stephen.day@docker.com>