And fix failing test along the way:
```
2022-11-11T12:37:47.0413934Z === RUN TestResetDB
2022-11-11T12:37:47.0414557Z 2022-11-11T12:36:54.510Z INFO initial gas supply is not set or wrong, setting default value {"InitialGASSupply": "52000000"}
2022-11-11T12:37:47.0415288Z 2022-11-11T12:36:54.510Z INFO MaxBlockSize is not set or wrong, setting default value {"MaxBlockSize": 262144}
2022-11-11T12:37:47.0416020Z 2022-11-11T12:36:54.510Z INFO MaxBlockSystemFee is not set or wrong, setting default value {"MaxBlockSystemFee": 900000000000}
2022-11-11T12:37:47.0416786Z 2022-11-11T12:36:54.510Z INFO MaxTransactionsPerBlock is not set or wrong, using default value {"MaxTransactionsPerBlock": 512}
2022-11-11T12:37:47.0417725Z 2022-11-11T12:36:54.510Z INFO MaxValidUntilBlockIncrement is not set or wrong, using default value {"MaxValidUntilBlockIncrement": 5760}
2022-11-11T12:37:47.0418415Z 2022-11-11T12:36:54.510Z INFO Hardforks are not set, using default value
2022-11-11T12:37:47.0419272Z 2022-11-11T12:36:54.523Z INFO no storage version found! creating genesis block
2022-11-11T12:37:47.0419997Z 2022-11-11T12:36:54.529Z INFO chain is already at the proper state {"height": 0}
2022-11-11T12:37:47.0420974Z testing.go:1097: TempDir RemoveAll cleanup: remove C:\Users\RUNNER~1\AppData\Local\Temp\TestResetDB671187463\001\chains\privnet\000001.log: The process cannot access the file because it is being used by another process.
2022-11-11T12:37:47.0421606Z --- FAIL: TestResetDB (1.99s)
```
zap never closes open sinks except its own tests. This behaviour
prevents TestHandleLoggingParams from successful cleanup because
temp log output file can't be closed due to the following error:
```
TempDir RemoveAll cleanup: remove C:\\Users\\Anna\\AppData\\Local\\Temp\\TestHandleLoggingParams_debug5796883
33\\001\\file.log: The process cannot access the file because it is being used by another process.
```
So this tremendous cludge is made mosetly for our testing code.
It is not for concurrent usage (we don't have cases of
multithreaded access to logger output sink).
Problem:
```
--- FAIL: TestHandleLoggingParams (0.02s)
--- FAIL: TestHandleLoggingParams/default (0.00s)
server_test.go:51:
Error Trace: server_test.go:51
Error: Received unexpected error:
couldn't open sink "C:\\Users\\Anna\\AppData\\Local\\Temp\\TestHandleLoggingParams226652490\\001/file.log": no sink found for scheme "c"
Test: TestHandleLoggingParams/default
--- FAIL: TestHandleLoggingParams/debug (0.00s)
server_test.go:64:
Error Trace: server_test.go:64
Error: Received unexpected error:
couldn't open sink "C:\\Users\\Anna\\AppData\\Local\\Temp\\TestHandleLoggingParams226652490\\001/file.log": no sink found for scheme "c"
Test: TestHandleLoggingParams/debug
```
Solution:
Currently no solution is implemented, but we can use relative paths instead of absolute.