After recent changes network configuration stored in the Netmap contract
of the NeoFS Sidechain contains `MaintenanceModeAllowed` flag. There is
a need to support this value in Storage node application.
Make `NetmapService.NetworkInfo` RPC server of the storage node to set
`MaintenanceModeAllowed` flag according to corresponding value in the
Sidechain.
Signed-off-by: Leonard Lyubich <leonard@nspcc.ru>
After recent changes in the NeoFS API protocol network configuration
contains `MaintenanceModeAllowed` boolean flag. There is a need to
support the config value in all NeoFS applications.
Provide `Client.MaintenanceModeAllowed` method which read the config
from the Sidechain. Extend `NetworkConfiguration` structure with
`MaintenanceModeAllowed` field.
Signed-off-by: Leonard Lyubich <leonard@nspcc.ru>
`NetworkConfiguration` represents NeoFS network configuration stored in
the Sidechain. In previous implementation the configuration missed flag
of disabled homomorphic hashing.
Add `NetworkConfiguration.HomomorphicHashingDisabled` boolean field.
Decode the field in `Client.ReadNetworkConfiguration` method. Print this
value in `netmap netinfo` command of NeoFS CLI.
Signed-off-by: Leonard Lyubich <leonard@nspcc.ru>
`readBoolConfig` method is going to be reused for reading other
configuration values. All boolean settings are `false` by default, so it
makes sense to return default value on missing key directly from
`readBoolConfig`.
Handle `ErrConfigNotFound` case in `readBoolConfig` method. Change
`HomomorphicHashDisabled` method to call `readBoolConfig` directly.
Signed-off-by: Leonard Lyubich <leonard@nspcc.ru>
There is a need to prevent limitless abuse of MAINTENANCE status of the
storage nodes. To do this, configuration of the NeoFS network is going
to be extended with the flag which allows the state. Until this is done,
it makes sense to prepare a site for this in the code.
Define `state.NetworkSettings` interface as an abstraction of global
network configuration within the `state` package. Make
`NetMapCandidateValidator` to depend on `NetworkSettings` and provide
corresponding field setter. Change `VerifyAndUpdate` method's behavior
to return an error for candidates with MAINTENANCE state if this state
is disallowed by the network configuration. Provide `NetworkSettings`
from the wrapper over Netmap contract's client on Inner Ring application
side. The provider is implemented to statically disallow MAINTENANCE
mode in order to save previous behavior.
Signed-off-by: Leonard Lyubich <leonard@nspcc.ru>
Signed-off-by: Leonard Lyubich <ctulhurider@gmail.com>
New network status of storage nodes is going to be introduced. To
simplify the addition, it would be useful to prepare the code for this.
Signed-off-by: Leonard Lyubich <leonard@nspcc.ru>
In previous implementation storage node interpreted all status values
sent in `SetNetmapStatus` RPC as `OFFLINE` except `ONLINE` and
`MAINTENANCE`. This could lead to incorrect processing of new values,
and also didn't allow detection of problems with sending garbage values.
Make implementation of `NodeState` interface used by Control API server
to deny requests with statuses other than protocol-declared enum.
Signed-off-by: Leonard Lyubich <leonard@nspcc.ru>
In previous implementation Inner Ring allowed storage nodes with any
state to register in the network. According to the current design, only
nodes with ONLINE state are allowed to enter the network map.
Create new `state` sub-package of `nodevalidation` package of Inner Ring
application. Define `state.NetMapCandidateValidator` type and provide
`NodeValidator` interface required by the Inner Ring's processor of
`Netmap` contract's notification events. Embed new validator into the
one used by the Inner Ring application.
From now all `AddPeer` notifications with node state other than `ONLINE`
will be denied.
Signed-off-by: Leonard Lyubich <leonard@nspcc.ru>
Degraded mode allows us to operate without an SSD,
thus writecache should be unavailable in this mode.
Signed-off-by: Evgenii Stratonikov <evgeniy@morphbits.ru>
Add a common error for this case because it is not an error
which should increase error counter. Single error simplifies checks on
the call-site.
Signed-off-by: Evgenii Stratonikov <evgeniy@morphbits.ru>
It will allow rereading config values and will simplify distinguishing them
from the custom values in the `cfg` structure.
Signed-off-by: Pavel Karpy <carpawell@nspcc.ru>
Negative values have no sense. On the other hand it differs from the
blobovnicza's configuration and prevents unification.
Signed-off-by: Pavel Karpy <carpawell@nspcc.ru>
Allow user to initiate flushing objects from a writecache.
We need this in 2 cases:
1. During writecache storage schema update, it should be flushed with
the old version of node and started clean with a new one.
2. During SSD replacement, to avoid data loss.
Signed-off-by: Evgenii Stratonikov <evgeniy@morphbits.ru>
Replace `ProcessCurrentNetMap` method of `NodeState` interface with
`ReadCurrentNetMap` one with two changes:
* Replace network map type from NeoFS SDK package with the
protocol-generated message. This replaces all the business logic to
the application layer.
* Support error return. This allows to cover problem node states.
Return an error from `NodeState.ReadCurrentNetMap` method implemeted
through `atomic.Value` if `Store` method has not been called yet.
Signed-off-by: Leonard Lyubich <leonard@nspcc.ru>