Target container ID is taken from tombstone: cmd/frostfs-node/object.go:507
Also object of type `TOMBSTONE` contains objectID, so tombstone and
tombstoned object must have the same containerID.
Signed-off-by: Dmitrii Stepanov <d.stepanov@yadro.com>
For EC chunks need to return EC parent object ID as
EC chunks don't have own attributes but inherit parent's.
Signed-off-by: Dmitrii Stepanov <d.stepanov@yadro.com>
Do not fail on same latest version to run compact on upgraded metabase.
Use NoSync on compact.
Log every batch on bucket delete stage.
Signed-off-by: Dmitrii Stepanov <d.stepanov@yadro.com>
Since Go 1.22 a "for" statement with a "range" clause is able
to iterate through integer values from zero to an upper limit.
gopatch script:
@@
var i, e expression
@@
-for i := 0; i <= e - 1; i++ {
+for i := range e {
...
}
@@
var i, e expression
@@
-for i := 0; i <= e; i++ {
+for i := range e + 1 {
...
}
@@
var i, e expression
@@
-for i := 0; i < e; i++ {
+for i := range e {
...
}
Signed-off-by: Ekaterina Lebedeva <ekaterina.lebedeva@yadro.com>
When node put chunk into EC container, `policer` may remove it as redundant.
This chunk marked as removed. When parent object removed and `gc` start iterating over chunk,
node count removing chunk twice.
Signed-off-by: Anton Nikiforov <an.nikiforov@yadro.com>
EC parent and split gc marks should be deleted after last EC chunk delete.
Also should delete split info for EC parent and split parent.
Signed-off-by: Dmitrii Stepanov <d.stepanov@yadro.com>
It is required to save split parent ID too, not only split ID.
Otherwise inhume operation works incorrect: shard with last part may be skipped
and parent object will be available.
Signed-off-by: Dmitrii Stepanov <d.stepanov@yadro.com>
For REP updating split info is handled explicitly by a high-level PUT logic.
For EC it is trickier, because the address of an object we put is only
distantly related to a split info.
Signed-off-by: Evgenii Stratonikov <e.stratonikov@yadro.com>
* If EC-parent is a part of Split itself, then save to root bucket
its parent;
* If EC-parent is not a part of Split itself, then save to root bucket
OID of this EC-parent.
Signed-off-by: Airat Arifullin <a.arifullin@yadro.com>
* `GetECHeader` is not correct way to determine if an object's got
EC-header: `ECHeader` must be used for that.
Signed-off-by: Airat Arifullin <a.arifullin@yadro.com>
metabase.Open() now reports metabase mode metric. shard.UpdateID()
needs to read shard ID from metabase => needs to open metabase.
It caused reporting 'shard undefined' metrics. To avoid reporting
wrong metrics metabase.GetShardID() was added which also opens
metabase and does not report metrics.
Signed-off-by: Ekaterina Lebedeva <ekaterina.lebedeva@yadro.com>
It used to always show CLOSED regardless of actual mode.
Now metric represents actual metabase mode of operations.
Signed-off-by: Ekaterina Lebedeva <ekaterina.lebedeva@yadro.com>
`fmt.Errorf can be replaced with errors.New` and `fmt.Sprintf can be replaced with string addition`
Signed-off-by: Dmitrii Stepanov <d.stepanov@yadro.com>
There may be a race condition between put an object and
flushing the writecache:
1. Put object to the writecache
2. Writecache flushes object to the blobstore and sets blobstore's
storageID
3. Put object to the metabase, set writecache's storageID
Signed-off-by: Dmitrii Stepanov <d.stepanov@yadro.com>
Most of the time it exits, e.g. when it is per-container and use on each
object PUT. Bbolt implementation first tries to create bucket and then
returns it if it exists. Create operation uses cursor and thus is not
very lightweight, we can avoid it.
```
goos: linux
goarch: amd64
pkg: git.frostfs.info/TrueCloudLab/frostfs-node/pkg/local_object_storage/metabase
cpu: 11th Gen Intel(R) Core(TM) i5-1135G7 @ 2.40GHz
│ old │ new │
│ sec/op │ sec/op vs base │
Put/parallel-8 174.4µ ± 3% 163.3µ ± 3% -6.39% (p=0.000 n=10)
Put/sequential-8 263.3µ ± 2% 259.0µ ± 1% -1.64% (p=0.000 n=10)
geomean 214.3µ 205.6µ -4.05%
│ old │ new │
│ B/op │ B/op vs base │
Put/parallel-8 275.3Ki ± 3% 281.1Ki ± 4% ~ (p=0.063 n=10)
Put/sequential-8 413.0Ki ± 2% 426.6Ki ± 2% +3.29% (p=0.003 n=10)
geomean 337.2Ki 346.3Ki +2.70%
│ old │ new │
│ allocs/op │ allocs/op vs base │
Put/parallel-8 678.0 ± 1% 524.5 ± 2% -22.64% (p=0.000 n=10)
Put/sequential-8 1.329k ± 0% 1.183k ± 0% -10.91% (p=0.000 n=10)
geomean 949.1 787.9 -16.98%
```
Signed-off-by: Evgenii Stratonikov <e.stratonikov@yadro.com>