test object PUT with chunked transfer enconding
Before the RGW fix PR was responding with 411 instead of 200
RGW fix PR: https://github.com/ceph/ceph/pull/50235
Signed-off-by: Mark Kogan <mkogan@redhat.com>
(cherry picked from commit 13a9bfc00a
)
This commit is contained in:
parent
67e6c5aecc
commit
6342b3d258
1 changed files with 13 additions and 0 deletions
|
@ -1573,6 +1573,19 @@ def test_object_write_to_nonexist_bucket():
|
|||
assert error_code == 'NoSuchBucket'
|
||||
|
||||
|
||||
def _ev_add_te_header(request, **kwargs):
|
||||
request.headers.add_header('Transfer-Encoding', 'chunked')
|
||||
|
||||
def test_object_write_with_chunked_transfer_encoding():
|
||||
bucket_name = get_new_bucket()
|
||||
client = get_client()
|
||||
|
||||
client.meta.events.register_first('before-sign.*.*', _ev_add_te_header)
|
||||
response = client.put_object(Bucket=bucket_name, Key='foo', Body='bar')
|
||||
|
||||
assert response['ResponseMetadata']['HTTPStatusCode'] == 200
|
||||
|
||||
|
||||
def test_bucket_create_delete():
|
||||
bucket_name = get_new_bucket()
|
||||
client = get_client()
|
||||
|
|